• InfoWater Pro

Assign wave speeds to pipes

Edit the wave speed of individual pipes and groups of pipes.


Tutorial resources

These downloadable resources will be used to complete this tutorial:

Setting_global_surge_options_for_surge_analysis_datasets.zip

Step-by-step guide

When working in InfoSurge Pro, pipes can have different wave speeds due to several factors, including the liquid used, the pipe material, wall thickness, and pipe internal diameters. In this example, a wave speed is assigned to an individual pipe, and then the wave speeds of multiple pipes are edited as a group.

  1. Double-click the desired project .aprx file to open ArcGIS Pro.
  2. Click the InfoWater Pro tab to open the InfoWater Pro ribbon.
  3. In the Project panel, click Initialize.
  4. From the map, click pipe 11 to select it.

This is the pipe that will be assigned a wave speed value.

  1. In the Model Explorer, click the Pipe Wave Speed button.

In the ArcGIS interface, with InfoWater Pro initialized, pipe 11 highlighted on the map, and in the Model Explorer, the Pipe Wave Speed button selected.

  1. In the Pipe Surge Data dialog box, in the Wave Speed field, enter “4200” feet per second.

This value will overwrite the Global Wave Speed field in the Run Manager.

  1. Click Create to save the wave speed setting and exit the dialog box.

The Pipe Surge Data dialog box, with 4200 feet per second entered in the Wave Speed field, and Create selected.

Next, edit the wave speeds of a group of pipes:

  1. From the InfoWater Pro ribbon, Domain panel, click the Enlarge Domain button.

In the InfoWater Pro ribbon, Domain panel, the Enlarge Domain button called out with a red arrow.

  1. From the map, select several pipes—in this example, pipes 22, 122, and 113 are selected.
  2. From the ribbon, Edit panel, click the Group Editing button.

In the map, several pipes selected for this example, and in the ribbon, Edit panel, Group Editing highlighted in red.

  1. In the Group Editing dialog box, enable Domain.
  2. In the list, scroll to find and select Pipe Wave Speed.
  3. In the Wave Speed field, enter “1500”.
  4. Click Apply to overwrite the existing wave speed of the pipes in the domain.

The Group Editing dialog box, with settings for this example configured and highlighted in red, and Apply selected.

  1. In the confirmation popup, click OK.
  2. Click Close to exit the dialog box.

Pipe wave speeds can be calculated using the InfoSurge Wave Speed Calculator, and then assigned as desired to specific pipes with similar criteria.

  1. To open this calculator, from the Model Explorer, click the Auxiliary Calculator button and select Wave Speed.

In the Model Explorer, the Auxiliary Calculator drop-down with Wave Speed selected and highlighted in red.

In the InfoSurge Calculator dialog box, on the Wave Speed tab, properties can be changed to determine an estimated wave speed for the selected pipe.

The InfoSurge Calculator dialog box, Wave Speed tab, with properties that can be changed to determine an estimated wave speed for the selected pipe.

Using the correct wave speed is essential for the accurate calculation of the magnitude of pressure surges in the system.