• Civil 3D

Run interference checks and create tables and reports

Run interference checks, add pipe network tables, and generate reports.


00:04

Now we're going to continue in this drawing and

00:06

check for clashes between the storm and sanitary networks

00:11

from prospector under networks. Right? Click on interference checks

00:16

and choose create interference check

00:20

in the drawing. Pick a part on the storm network

00:24

and then pick a part on the sanitary network

00:28

in the crate interference check dialogue.

00:31

Click on 3d proximity check criteria

00:34

apply, 3D proximity check should be selected,

00:39

the used distance should be set to 1 ft.

00:42

This will check for parts that are closer together than 1 ft.

00:47

Click. OK?

00:49

And then click. OK. Again,

00:52

civil 3D will run the interference check

00:56

and then display a message

00:58

showing how many interferences were found

01:01

in prospector. Select the newly created interference check

01:06

in the item list view.

01:07

Click on the first interference,

01:10

right click and choose zoom to

01:14

review the interference.

01:17

Repeat this for the second interference check

01:22

this time there's not a hard clash but it's a proximity clash.

01:28

You could now adjust the networks to remove the interferences.

01:32

Now we'll create a table in the drawing from our storm network

01:37

from the annotate ribbon tab

01:39

labels and tables panel,

01:40

click on add tables

01:43

then pipe network

01:45

then add structure

01:48

in the structure table dialogue set the table style to structure with pipes

01:55

by network is selected and the network should be set to storm one

02:00

click. OK. To create the table

02:03

place the table in the drawing away from the design.

02:07

The table displays the structural information

02:10

as well as details of both the incoming and outgoing pipes.

02:16

Note that the structures are not displayed in any order

02:21

to sort the table, select it then right click and choose edit table style

02:28

in the table style on the data properties, tab,

02:31

select sort data

02:33

and ensure the sorting column is set to one

02:36

and then click. OK.

02:39

The table in the drawing is now sorted properly.

02:43

Finally, we'll create a report from our networks

02:48

in the tool space. Click on the toolbox tab,

02:51

expand reports manager,

02:54

then expand pipes,

02:57

select the pipes and structures report

02:60

right click choose, execute

03:03

in the export to

03:04

XML dialogue, deselect everything,

03:07

then scroll down

03:09

and select pipe networks

03:12

and then click OK.

03:15

Set the report type to html

03:18

and enter a name for the report.

03:21

Quick. Save

03:23

the report should open in a web browser.

03:28

It contains information about the structures and pipes

03:32

for both the storm and sanitary networks.

Video transcript

00:04

Now we're going to continue in this drawing and

00:06

check for clashes between the storm and sanitary networks

00:11

from prospector under networks. Right? Click on interference checks

00:16

and choose create interference check

00:20

in the drawing. Pick a part on the storm network

00:24

and then pick a part on the sanitary network

00:28

in the crate interference check dialogue.

00:31

Click on 3d proximity check criteria

00:34

apply, 3D proximity check should be selected,

00:39

the used distance should be set to 1 ft.

00:42

This will check for parts that are closer together than 1 ft.

00:47

Click. OK?

00:49

And then click. OK. Again,

00:52

civil 3D will run the interference check

00:56

and then display a message

00:58

showing how many interferences were found

01:01

in prospector. Select the newly created interference check

01:06

in the item list view.

01:07

Click on the first interference,

01:10

right click and choose zoom to

01:14

review the interference.

01:17

Repeat this for the second interference check

01:22

this time there's not a hard clash but it's a proximity clash.

01:28

You could now adjust the networks to remove the interferences.

01:32

Now we'll create a table in the drawing from our storm network

01:37

from the annotate ribbon tab

01:39

labels and tables panel,

01:40

click on add tables

01:43

then pipe network

01:45

then add structure

01:48

in the structure table dialogue set the table style to structure with pipes

01:55

by network is selected and the network should be set to storm one

02:00

click. OK. To create the table

02:03

place the table in the drawing away from the design.

02:07

The table displays the structural information

02:10

as well as details of both the incoming and outgoing pipes.

02:16

Note that the structures are not displayed in any order

02:21

to sort the table, select it then right click and choose edit table style

02:28

in the table style on the data properties, tab,

02:31

select sort data

02:33

and ensure the sorting column is set to one

02:36

and then click. OK.

02:39

The table in the drawing is now sorted properly.

02:43

Finally, we'll create a report from our networks

02:48

in the tool space. Click on the toolbox tab,

02:51

expand reports manager,

02:54

then expand pipes,

02:57

select the pipes and structures report

02:60

right click choose, execute

03:03

in the export to

03:04

XML dialogue, deselect everything,

03:07

then scroll down

03:09

and select pipe networks

03:12

and then click OK.

03:15

Set the report type to html

03:18

and enter a name for the report.

03:21

Quick. Save

03:23

the report should open in a web browser.

03:28

It contains information about the structures and pipes

03:32

for both the storm and sanitary networks.

Was this information helpful?